PT - JOURNAL ARTICLE AU - RUSTAGI, TARUSH AU - BOUREKAS, ERIC AU - MENDEL, EHUD TI - Floating Vertebral Body Cement Ball After High-Viscosity-Cement Vertebroplasty for Lytic Defect: Report of 2 Cases AID - 10.14444/7079 DP - 2020 Aug 01 TA - International Journal of Spine Surgery PG - 594--598 VI - 14 IP - 4 4099 - https://www.ijssurgery.com/content/14/4/594.short 4100 - https://www.ijssurgery.com/content/14/4/594.full SO - Int J Spine Surg2020 Aug 01; 14 AB - Background Percutaneous vertebroplasty (PVP) is an effective procedure for painful pathological vertebral fractures. High-viscosity cement is the preferred choice for vertebroplasty given its low risk of extravasation. We describe here 2 cases of high-viscosity cement vertebroplasty in large lytic defects and associated complications.Case Description Case 1 describes PVP in an 89-year-old male patient with L1 pathological fracture from prostrate metastasis. Case 2 describes PVP in a 68-year-old male with T7 and T8 vertebral fractures from multiple myeloma. In both cases, high-viscosity cement was used to fill large lytic cavities. This resulted in poor interdigitation of the cement with the trabeculae forming an unstable floating cement ball and dangerous retrieval of the cement trocar needle. The implications of this occurrence have been described.Conclusions High-viscosity-cement vertebroplasty in large lytic defects needs to be done with caution. The potential occurrence of poor cement interdigitation and the following complications can be catastrophic, and caution must be used.