RT Journal Article SR Electronic T1 Morphometric Analysis of Subaxial Cervical Spine Pedicles in a Middle Eastern Population JF International Journal of Spine Surgery JO Int J Spine Surg FD International Society for the Advancement of Spine Surgery SP 8061 DO 10.14444/8061 A1 Alsaleh, Khalid A1 Essbaiheen, Fahad A1 Aldosari, Khalifah A1 Alsubei, Bandar A1 Alabdulkareeem, Mahammad YR 2021 UL https://www.ijssurgery.com/content/early/2021/04/30/8061.abstract AB Background Pedicle screw instrumentation of the posterior cervical spine is the most secure form of fixation available to surgeons. It has not achieved widespread use yet in the Middle East, mostly due to concerns regarding its feasibility in the target population. A detailed morphometric analysis of the lower cervical spine pedicles using computerized tomography (CT) was proposed to address this issue.Methods Two hundred and seventy patients were enrolled in the study. CT scans were reviewed by two experienced assessors, and measurements of pedicle width (PW), height (PH), and transverse angle (TA) were recorded for all patients. Interobserver and intraobserver reliability were calculated using the kappa statistic. Sex differences were also recorded and analyzed. The t test was used to assess for any significant differences in measurements due to sex (P < .05).Results The mean PW varied from 4.4 mm in C3 to 6.1 mm in C7. The mean PH was 6.4 mm in C3 and 6.8 mm in C7. Pedicle TA varied from 42 to 51 degrees between the different levels. Sex differences were observed and were statistically significant for PW and PH. Interobserver reliability was high for PW and PH, but was low for TA. Intraobserver reliability was 0.99 for both assessors.Conclusion This study provides reliable PW and PH measurements and demonstrates that cervical pedicle screw instrumentation is feasible in our local population. Significant variability exists, however, and each patient must be addressed individually for best results.Level of Evidence 3.Clinical Relevance This study shows that the morphology of the subaxial cervical pedicle permits instrumentation in a majority of cases of our target population.