High-resolution ICP–MS determination of Ti, V, Cr, Co, Ni, and Mo in human blood and urine of patients implanted with a hip or knee prosthesis

  • Technical Note
  • Published:
Analytical and Bioanalytical Chemistry Aims and scope Submit manuscript

Abstract

The main components (Ti, V, Cr, Co, Ni, and Mo) of metallic alloys currently used in hip and knee articular prostheses have been simultaneously determined in human whole blood and urine of implanted people by a (HR)-ICP–MS method previously developed in our laboratory. The determination of those elements has been carried out in patients with knee and hip prosthesis and in a group of pre-operation patients without any metallic device in their bodies, used as controls, demonstrating the usefulness of this technique to perform multielement analysis at ppt levels in complex matrices. The concentrations of V, Cr, Co, Ni, and Mo in urine and blood of implanted people turned out to be very similar to those obtained in control patients. However, raised Ti levels could be found both in urine and blood of patients with articular prostheses made or coated with a titanium alloy (Ti6Al4V).

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1

Similar content being viewed by others

References

  1. Jacobs JJ, Skipor AK, Patterson LM, Hallab NJ, Paprosky WG, Galante JO (1998) J Bone Joint Surg 80:1447–1458

    CAS  Google Scholar 

  2. Jacobs JJ, Skipor AK, Doorn PF, Campbell P, Schmalzried TP, Black J, Amstutz HC (1996) Clin Orthopaed Related Res 329:S256–S263

    Article  Google Scholar 

  3. Brodner W, Bitzan P, Meisinger V, Kaider A, Gottsauner-Wolf F, Kptz R (1997) J Bone Joint Surg 79-B(2):316–321

    Article  Google Scholar 

  4. Jacobs JJ, Skipor AK, Black G, Urban RM, Galante JO (1991) J Bone Joint Surg 73:1475–1486

    CAS  Google Scholar 

  5. Visuri T, Pukkala E, Paavolainen P, Pulkkinen P, Riska EB (1996) Clin Orthopaed Related Res 329S:S280–S289

    Article  Google Scholar 

  6. Gillespie WJ, Henry DA, O’Connell DL, Kendrick S, Juszczak E, McInneny K, Derby L (1996) Clin Orthopaed Related Res 329S:S290–S296

    Article  Google Scholar 

  7. Nyrén O, McLaughlin JK, Gridley G, Ekbom A, Johnell O, Fraumeni JF, Adami HO (1995) J Nat Cancer Inst 87:28–33

    Article  Google Scholar 

  8. Case PC, Ellis L, Turner JC, Fairman B (2001) Clin Chem 47:275–280

    CAS  Google Scholar 

  9. Rodushkin I, Odman F, Branth S (1999) Fresenius J Anal Chem 364:338–346

    Article  CAS  Google Scholar 

  10. Rodushkin I, Odman F (2001) J Trace Elements Med Biol 14:241–247

    Article  CAS  Google Scholar 

  11. Marchante Gayón JM, Sariego Muñiz C, García Alonso JI, Sanz Medel A (1999) Anal Chim Acta 400:241–247

    Article  Google Scholar 

  12. Sariego Muñiz C, Marchante Gayón JM, García Alonso JI, Sanz Medel A (1999) J Anal At Spectrom 14:193–198

    Article  Google Scholar 

  13. Sarmiento-González A, Marchante-Gayón JM, Tejerina-Lobo JM, Paz-Jiménez J, Sanz-Medel A (2005) Anal Bioanal Chem 382:1001–1009

    Article  Google Scholar 

  14. Cornelis R, Heinzowi B, Herber RFM, Molin Christensen J, Poulsen OM, Sabbioni E, Templeton DM, Thomassen Y, Vahter M, Vesterberg O (1996) J Trace Elements Med Biol 10:103–127

    CAS  Google Scholar 

  15. Pineau A, Guillard O, Chappuis P, Arnaud J, Zawislak R (1993) Crit Rev Clin Lab Sci 30:203–222

    Article  CAS  Google Scholar 

  16. Lapitajs G, Greb U, Dunemann L, Begerow J, Moens L, Verrept P (1995) Int Lab 6:21–27

    Google Scholar 

  17. Sariego Muñiz C, Marchante Gayón JM, García Alonso JI, Sanz Medel A (1998) J Anal At Spectrom 13:283–287

    Article  Google Scholar 

  18. Rodushkin I, Determination of trace and ultratrace elements in body fluids using sector-field ICP–MS. Thermo Finnigan application flash report no. E11

Download references

Acknowledgements

The authors gratefully acknowledge the financial support provided by Acuña y Fombona S.A, FICYT (project PC-SPV01–06) and the Ministry of Science and Technology of Spain (project MCT-03-BQU-04671). Help from Meike Hamester and Torsten Lindemann of Thermo Fisher Scientific and Andreas Klügel and Heike Anders of the Department of Petrology of the Oceanic Crust of the University of Bremen is specially acknowledged.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Alfredo Sanz-Medel.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Sarmiento-González, A., Marchante-Gayón, J.M., Tejerina-Lobo, J.M. et al. High-resolution ICP–MS determination of Ti, V, Cr, Co, Ni, and Mo in human blood and urine of patients implanted with a hip or knee prosthesis. Anal Bioanal Chem 391, 2583–2589 (2008). https://doi.org/10.1007/s00216-008-2188-4

Download citation

  • Received:

  • Revised:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s00216-008-2188-4

Keywords

Navigation