Abstract
The main components (Ti, V, Cr, Co, Ni, and Mo) of metallic alloys currently used in hip and knee articular prostheses have been simultaneously determined in human whole blood and urine of implanted people by a (HR)-ICP–MS method previously developed in our laboratory. The determination of those elements has been carried out in patients with knee and hip prosthesis and in a group of pre-operation patients without any metallic device in their bodies, used as controls, demonstrating the usefulness of this technique to perform multielement analysis at ppt levels in complex matrices. The concentrations of V, Cr, Co, Ni, and Mo in urine and blood of implanted people turned out to be very similar to those obtained in control patients. However, raised Ti levels could be found both in urine and blood of patients with articular prostheses made or coated with a titanium alloy (Ti6Al4V).
Similar content being viewed by others
References
Jacobs JJ, Skipor AK, Patterson LM, Hallab NJ, Paprosky WG, Galante JO (1998) J Bone Joint Surg 80:1447–1458
Jacobs JJ, Skipor AK, Doorn PF, Campbell P, Schmalzried TP, Black J, Amstutz HC (1996) Clin Orthopaed Related Res 329:S256–S263
Brodner W, Bitzan P, Meisinger V, Kaider A, Gottsauner-Wolf F, Kptz R (1997) J Bone Joint Surg 79-B(2):316–321
Jacobs JJ, Skipor AK, Black G, Urban RM, Galante JO (1991) J Bone Joint Surg 73:1475–1486
Visuri T, Pukkala E, Paavolainen P, Pulkkinen P, Riska EB (1996) Clin Orthopaed Related Res 329S:S280–S289
Gillespie WJ, Henry DA, O’Connell DL, Kendrick S, Juszczak E, McInneny K, Derby L (1996) Clin Orthopaed Related Res 329S:S290–S296
Nyrén O, McLaughlin JK, Gridley G, Ekbom A, Johnell O, Fraumeni JF, Adami HO (1995) J Nat Cancer Inst 87:28–33
Case PC, Ellis L, Turner JC, Fairman B (2001) Clin Chem 47:275–280
Rodushkin I, Odman F, Branth S (1999) Fresenius J Anal Chem 364:338–346
Rodushkin I, Odman F (2001) J Trace Elements Med Biol 14:241–247
Marchante Gayón JM, Sariego Muñiz C, García Alonso JI, Sanz Medel A (1999) Anal Chim Acta 400:241–247
Sariego Muñiz C, Marchante Gayón JM, García Alonso JI, Sanz Medel A (1999) J Anal At Spectrom 14:193–198
Sarmiento-González A, Marchante-Gayón JM, Tejerina-Lobo JM, Paz-Jiménez J, Sanz-Medel A (2005) Anal Bioanal Chem 382:1001–1009
Cornelis R, Heinzowi B, Herber RFM, Molin Christensen J, Poulsen OM, Sabbioni E, Templeton DM, Thomassen Y, Vahter M, Vesterberg O (1996) J Trace Elements Med Biol 10:103–127
Pineau A, Guillard O, Chappuis P, Arnaud J, Zawislak R (1993) Crit Rev Clin Lab Sci 30:203–222
Lapitajs G, Greb U, Dunemann L, Begerow J, Moens L, Verrept P (1995) Int Lab 6:21–27
Sariego Muñiz C, Marchante Gayón JM, García Alonso JI, Sanz Medel A (1998) J Anal At Spectrom 13:283–287
Rodushkin I, Determination of trace and ultratrace elements in body fluids using sector-field ICP–MS. Thermo Finnigan application flash report no. E11
Acknowledgements
The authors gratefully acknowledge the financial support provided by Acuña y Fombona S.A, FICYT (project PC-SPV01–06) and the Ministry of Science and Technology of Spain (project MCT-03-BQU-04671). Help from Meike Hamester and Torsten Lindemann of Thermo Fisher Scientific and Andreas Klügel and Heike Anders of the Department of Petrology of the Oceanic Crust of the University of Bremen is specially acknowledged.
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Sarmiento-González, A., Marchante-Gayón, J.M., Tejerina-Lobo, J.M. et al. High-resolution ICP–MS determination of Ti, V, Cr, Co, Ni, and Mo in human blood and urine of patients implanted with a hip or knee prosthesis. Anal Bioanal Chem 391, 2583–2589 (2008). https://doi.org/10.1007/s00216-008-2188-4
Received:
Revised:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s00216-008-2188-4