Robot-assisted total knee arthroplasty accurately restores the joint line and mechanical axis. A prospective randomised study
Robot-assisted Total Knee Arthroplasty (TKA) improves the accuracy and precision of
component implantation and mechanical axis (MA) alignment. Joint-line restoration in robot-…
component implantation and mechanical axis (MA) alignment. Joint-line restoration in robot-…
Robotic‐assisted total knee arthroplasty may lead to improvement in quality‐of‐life measures: a 2‐year follow‐up of a prospective randomized trial
Purpose Despite reduction in radiological outliers in previous randomized trials comparing
robotic‐assisted versus conventional total knee arthroplasty (TKA), no differences in short‐…
robotic‐assisted versus conventional total knee arthroplasty (TKA), no differences in short‐…
[HTML][HTML] THINK surgical TSolution-One®(Robodoc) total knee arthroplasty
THINK Surgical TSolution-One® is an active-autonomous, image-based, robotic milling
system which enables the surgeon to attain a consistently accurate implant component …
system which enables the surgeon to attain a consistently accurate implant component …
Patient-reported outcomes, quality of life, and satisfaction rates in young patients aged 50 years or younger after total knee arthroplasty
Background Recent studies have shown a discrepancy between traditional functional outcomes
and patient satisfaction, with some reporting less than 85% satisfaction in older patients …
and patient satisfaction, with some reporting less than 85% satisfaction in older patients …
Are oxford hip score and western Ontario and McMaster Universities osteoarthritis index useful predictors of clinical meaningful improvement and satisfaction after …
… We observed a low ceiling for postoperative OHS MCID attainment (99.9%). This ceiling …
may be too low. This may be because of the scoring system or a low OHS standard deviation …
may be too low. This may be because of the scoring system or a low OHS standard deviation …
[HTML][HTML] Early experiences with robot-assisted total knee arthroplasty using the DigiMatch™ ROBODOC® surgical system
METHODS We prospectively recruited 27 consecutive patients who underwent robot-assisted
TKA between May and December 2012. Two patients were excluded from the study due to …
TKA between May and December 2012. Two patients were excluded from the study due to …
Accelerometer-based navigation is as accurate as optical computer navigation in restoring the joint line and mechanical axis after total knee arthroplasty: a …
The Zimmer iASSIST system is a novel accelerometer-based navigation system for TKA. 76
patients (76 knees) were prospectively matched for age, BMI, gender, diagnosis, and pre-…
patients (76 knees) were prospectively matched for age, BMI, gender, diagnosis, and pre-…
Critical shoulder angle and acromial index do not influence 24-month functional outcome after arthroscopic rotator cuff repair
Background: Recent studies have shown a correlation between scapular geometry and the
development of atraumatic rotator cuff tears. However, a paucity of literature is available on …
development of atraumatic rotator cuff tears. However, a paucity of literature is available on …
Metal-on-metal total hip arthroplasty: risk factors for pseudotumours and clinical systematic evaluation
MHL Liow, YM Kwon - International orthopaedics, 2017 - Springer
The potential advantages of contemporary MoM THA implants include less volumetric wear
with subsequent reduction of polyethylene wear-induced osteolysis and greater component …
with subsequent reduction of polyethylene wear-induced osteolysis and greater component …
Obesity and the absence of trochlear dysplasia increase the risk of revision in patellofemoral arthroplasty
Purpose Proper indications and patient selection are of paramount importance in patellofemoral
arthroplasty (PFA). Although factors predicting outcomes in total knee arthroplasty (TKA) …
arthroplasty (PFA). Although factors predicting outcomes in total knee arthroplasty (TKA) …