An Internal Fixator for Posterior Application to Short Segments of the Thoracic, Lumbar, or Lumbosacral Spine Design and Testing.

MH Krag, BD BEYNNON, MH POPE… - … Research (1976-2007 …, 1986 - journals.lww.com
A new spinal implant has been designed and biomechanical testing completed, intended
for application to" short-segment" spinal defects such as disc degeneration, fracture, …

Evidence of connective tissue involvement in acupuncture

…, GJ Badger, JA Yandow, JR Fox, MH Krag - The FASEB …, 2002 - Wiley Online Library
Acupuncture needle manipulation gives rise to “needle grasp,” a biomechanical phenomenon
characterized by an increase in the force necessary to pull the needle out of the tissue (…

Morphometry of the thoracic and lumbar spine related to transpedicular screw placement for surgical spinal fixation

MH KRAG, DL WEAVER, BD BEYNNON, LD HAUGH - Spine, 1988 - journals.lww.com
Vertebral transpedicular screws provide secure attachment for posterior spinal fixation
devices. Screw design details, biomechanics, and implantation safety depend upon anatomic …

[HTML][HTML] Biomechanical response to acupuncture needling in humans

…, GJ Badger, BS Garra, MH Krag - Journal of applied …, 2001 - journals.physiology.org
During acupuncture treatments, acupuncture needles are manipulated to elicit the characteristic
“de qi” reaction widely viewed as essential to acupuncture's therapeutic effect. De qi has …

Biomechanics of thoracolumbar spinal fixation: A review

MH Krag - Spine, 1991 - journals.lww.com
Extensive development of spinal instrumentation has occurred recently, benefitted by
improved biomechanical knowledge. Reviewed here are various devices and the major …

Effects of disc injury on mechanical behavior of the human spine

MM Panjabi, MH Krag, TQ Chung - Spine, 1984 - journals.lww.com
The effects of injury to the intervertebral disc were investigated using three-dimensional
flexibility and creep measurements of functional spinal units from fresh cadaver lumbar spines. …

[HTML][HTML] Ultrasound evidence of altered lumbar connective tissue structure in human subjects with chronic low back pain

…, JR Fox, GJ Badger, NA Bouffard, MH Krag… - BMC musculoskeletal …, 2009 - Springer
Background Although the connective tissues forming the fascial planes of the back have been
hypothesized to play a role in the pathogenesis of chronic low back pain (LBP), there have …

Repair of failed transpedicle screw fixation: a biomechanical study comparing polymethylmethacrylate, milled bone, and matchstick bone reconstruction

BA Pfeifer, MH Krag, C Johnson - Spine, 1994 - journals.lww.com
In a random, controlled laboratory study, pedicle screws placed in human cadaveric vertebrae
were axially loaded to failure. Three repair methods were tested. Use of low pressure …

Depth of insertion of transpedicular vertebral screws into human vertebrae: effect upon screw-vertebra interface strength

MH Krag, BD Beynnon, MH Pope… - Clinical Spine …, 1988 - journals.lww.com
Improvement in the strength of the transpedicular screw-vertebra interface by increasing the
depth of screw insertion may provide improved performance of spinal implants using such …

Hole preparation techniques for transpedicle screws: Effect on pull-out strength from human cadaveric vertebrae

DC GEORGE, MH KRAG, CC JOHNSON, ME VAN HAL… - Spine, 1991 - journals.lww.com
In each of eight thoracolumbar human cadaveric vertebrae, a hole was made through one
pedicle into the vertebral body with a drill bit and through the contralatera1 pedicle with a …