Skip to main content

Main menu

  • Home
  • Content
    • Current Issue
    • Advance Online Publication
    • Archive
  • About Us
    • About ISASS
    • About the Journal
    • Author Instructions
    • Editorial Board
    • Reviewer Guidelines & Publication Criteria
  • More
    • Advertise
    • Subscribe
    • Alerts
    • Feedback
  • Join Us
  • Reprints & Permissions
  • Sponsored Content
  • Other Publications
    • ijss

User menu

  • My alerts

Search

  • Advanced search
International Journal of Spine Surgery
  • My alerts
International Journal of Spine Surgery

Advanced Search

  • Home
  • Content
    • Current Issue
    • Advance Online Publication
    • Archive
  • About Us
    • About ISASS
    • About the Journal
    • Author Instructions
    • Editorial Board
    • Reviewer Guidelines & Publication Criteria
  • More
    • Advertise
    • Subscribe
    • Alerts
    • Feedback
  • Join Us
  • Reprints & Permissions
  • Sponsored Content
  • Follow ijss on Twitter
  • Visit ijss on Facebook
Research ArticleLumbar Spine

Risk Factors for Adjacent Fractures After Cement-Augmented Thoracolumbar Pedicle Screw Instrumentation

FALKO SCHWARZ, MICHAELA BURCKHART, AARON LAWSON MCLEAN, ROLF KALFF and ALBRECHT WASCHKE
International Journal of Spine Surgery October 2018, 12 (5) 565-570; DOI: https://doi.org/10.14444/5069
FALKO SCHWARZ
Department for Neurosurgery, Jena University Hospital – Friedrich Schiller University Jena, Germany
MD
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
MICHAELA BURCKHART
Department for Neurosurgery, Jena University Hospital – Friedrich Schiller University Jena, Germany
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
AARON LAWSON MCLEAN
Department for Neurosurgery, Jena University Hospital – Friedrich Schiller University Jena, Germany
MD
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
ROLF KALFF
Department for Neurosurgery, Jena University Hospital – Friedrich Schiller University Jena, Germany
MD
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
ALBRECHT WASCHKE
Department for Neurosurgery, Jena University Hospital – Friedrich Schiller University Jena, Germany
MD
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • Article
  • Figures & Data
  • Info & Metrics
  • PDF
Loading

ABSTRACT

Background: The aim of our study was to identify factors that influence the occurrence of adjacent fractures in patients with cement-augmented pedicle screw instrumentation.

Methods: Data were retrospectively collected from medical charts and operative reports for every surgery in which cement-augmented instrumentation was used in our hospital of 4 consecutive years. A total of 93 operations were included and examined for gender, age, T-score, number of fused segments, number of implanted screws, broken screws, loosening of screws, leakage and distribution pattern of cement, pre- and postoperative kyphosis angle, revision surgery and adjacent fractures in follow-up. Categorical data were compared using the χ2 test or by Fisher's exact test, as appropriate. Continuous variables conforming to a normal distribution were compared using Student's t test. Otherwise the Mann-Whitney U test was applied. A P-value of <.05 was considered statistically significant. A trend was defined as a P < .2.

Results: The mean age was 68.1 years with a mean T-score of −3.12. Nineteen adjacent fractures occurred during follow-up and the median follow-up was 12 months (range, 1−27). Patients showed a higher risk for adjacent fractures following revision surgery (P = .016). Most fractures occurred superior to the instrumented level (P = .013) and in the first 12 months. Difference of T-score between the group “no adjacent fracture” and the group “adjacent fracture” was 0.7 (P = .138). Another trends were found in greater age (P = .119) and long instrumentations (P = .199).

Conclusions and Clinical Relevance: Revision surgeries are associated with a higher risk of adjacent fractures. In these cases, prophylactic kyphoplasty of the superior vertebra should be considered. This study is a retrospective, nonrandomized cohort/follow-up study.

Level of Evidence: 3.

  • adjacent fracture
  • spine surgery
  • osteoporosis
  • cement-augmented
  • pedicle screw instrumentation

INTRODUCTION

The proportion of elderly people is growing, particularly in industrialised countries.1–3 For this reason, there are a greater number of patients with reduced bone quality and consequent degenerative spine disease and osteoporotic fractures that require surgical treatment.1,2 In recent years, various surgical techniques have been developed to improve the fixation strength of implants in the osteoporotic spine, including supplemental laminar hooks, bicortical screw purchase, improved screw geometry and the augmentation of screws with bone cement.4 Cement-augmented pedicle screws are the most frequently used of these options in clinical practice.

Various cadaver studies have shown that fixation strength in osteoporotic bone is greater with cement-augmented screws than with noncement-augmented screws.5–7 Poly(methyl methacrylate) (PMMA) is the gold-standard cement for providing additional screw fixation. However, the use of cement carries its own risks, such as damage to neural structures, vascular injury, and pulmonary embolism caused by the leakage of cement out of the vertebral body. Furthermore, the biomechanical properties of the spine are altered when cement augmentation is used.1–3 In particular, there is greater stress on the vertebrae adjacent to the cement-augmented instrumentation, increasing the risk of subsequent fractures in these vertebrae.8,9

In this study, we examined the incidence of subsequent fractures in patients with decreased bone quality who received surgery involving cement-augmented pedicle screws. Herein, risk factors for the occurrence of subsequent fractures are identified.

MATERIALS AND METHODS

Patient Selection and Data Acquisition

This was a retrospective, single-center study. Between January 2010 and November 2013, a series of 87 patients with osteoporosis underwent 93 spinal instrumentation surgeries involving the application of high-viscosity PMMA cement (Confidence Spinal Cement System, DePuy Synthes, Indianapolis, Indiana) via a cannulated and perforated pedicle screw system (Viper 2, DePuy Synthes). These patients' demographic and clinical data were retrospectively collated from our institution's electronic record systems. Patients were clinically evaluated at each of the following time points after surgery: at 3, 6, 12, and 24 months. Postoperative bracing is not standard practice in our institution and none of the patients included in this study received a brace following surgery. In those patients who received bone grafts, local autologous bone was used.

The following variables were collected and included in analyses: patient age and sex, T-score, number of fused segments, number of implanted screws, number of broken screws, presence of screw loosening, particulars of the cement distribution pattern including any leakage, pre- and postoperative kyphosis angle, need for revision surgery, and occurrence of adjacent fracture during follow-up. The T-score was determined by preoperative quantitative computed tomography (QCT) of the first 3 lumbar vertebrae (L1 to L3). If any of these vertebrae were affected by pathology other than osteopenia or osteoporosis, the bone density of a neighboring vertebra was determined (eg, T12 or L4). Only patients with a T-score below −2.5 were included in this study. The kyphosis angle was ascertained from the midsagittal plane of a computed tomography (CT) scan. Here, the Cobb angle was determined between the endplates of the last instrumented (cranial and caudal) vertebral body. The degree of correction of kyphosis was determined as the difference between the preoperative kyphosis angle and the angle observed on the last radiological examination during the follow-up period.

Cement distribution and leakage pattern were analyzed on postoperative CT scans. The leakage pattern was classified as “prevertebral,” “paravertebral,” or “intraspinal.” The cement distribution was divided into the categories “concentrated” and “scattered.” Adjacent fractures were considered relevant only if they were both symptomatic and radiologically evident (on CT and/or magnetic resonance imaging scans).

Statistical Methods

SPSS Statistics for Windows version 22 (IBM, Armonk, New York) was used to perform statistical analyses. Variables were coded, depending on their characteristics, as nominal (eg, patient sex, presence of adjacent fracture, diagnosis), ordinal (eg, T-score) or metric (eg, body mass index, angular kyphosis, number of implanted screws). Discrete variables are expressed as counts (percentage) and continuous variables as means ± standard deviation (SD) or median and interquartile range (IQR) unless stated otherwise. Categorical data were compared using the χ2 test or by Fisher's exact test, as appropriate. Continuous variables conforming to a normal distribution were compared using Student's t-test. Otherwise the Mann-Whitney U test was applied. A P value of <.05 was considered statistically significant. A trend was defined as .05 < P < .2.

RESULTS

There were 41 males and 46 females in our cohort, with a mean patient age of 68.1 years (SD: 10.8 years; Table 1). Patients were followed postoperatively for a median of 12 months (range, 1–27 months). The most common indication for surgery was an unstable osteoporotic burst fracture (n = 42/87; 45.2%). A total of 513 cement-augmented screws were implanted (Figure 1). In most cases a screw was implanted in the second lumbar vertebra (n = 76/87). The mean T-score was −3.12. However, several patients in our cohort had a preexisting clinical diagnosis of osteoporosis; these patients (n = 9/87; 9.7%) did not receive a further QCT scan within the setting of the present study and they were not included in our calculation of the mean T-score for the cohort.

View this table:
  • View inline
  • View popup
  • Download powerpoint
Table 1

Patients characteristics with and without adjacent fractures.

Figure 1
  • Download figure
  • Open in new tab
  • Download powerpoint
Figure 1

Distribution of screw placement in the thoracic and lumbar spine.

Cement leakage was observed in 87/93 procedures (93.5%), relating to 236/515 screws (45.8%). Intradiscal cement leakage was observed in 2 cases; however, this leakage was not clinically relevant and the patients had no relevant signs or symptoms. A revision owing to cement leakage was necessary for one patient (n = 1/93; 1.1%); here a prevertebral cement leakage spread via the inferior vena cava into the right atrium and the patient underwent intervention at the hands of our institution's cardiac surgery team as a results.

In 78.5 % of all cases (n = 73/93) a concentrated cement distribution in the vertebral body was noted. Two screw cut-outs (n = 2/513; 0.38%) and 10 screw fractures (n = 10/513; 1.94%) were evident. In 3 of these 10 cases of screw fracture, pseudarthrosis was noted. Fifty percent (n = 6/12) of hardware failure occurred at the thoracolumbar junction. During the follow-up period, 19 adjacent fractures in 14 patients were observed (Table 2). Seventeen fractures (89%) were seen superior to the fused segments and 2 fractures occurred in an adjacent vertebra inferior to the fusion, which was a significant finding in bivariate analysis (P = .013). In cases in which an adjacent fracture was determined, there was a mean time to fracture occurrence of 8.5 months (range, 1–18 months). Most adjacent fractures appeared within the first 12 months following surgery (n = 15; 78.9%). Patients with an adjacent fracture had a mean T-score of −3.76 compared with −3.06 in patients without a fracture (Table 1). No statistically significant difference between these values was detected using the Mann-Whitney U test (P = .138).

View this table:
  • View inline
  • View popup
  • Download powerpoint
Table 2

Distribution of adjacent fractures.

In the subgroup of patients undergoing revision surgery, an adjacent fracture occurred in more than one third of cases (35.2%). Each of these patients was operated at least once before the revision surgery (median: 2; range, 1–4 times). In half of these cases (n = 7/14) a lumbar stenosis was the reason for the initial surgery. The first operation was a posterior lumbar interbody fusion in 10/14 cases (71.4%). Within this subgroup, there were a significantly higher number a fused segments (mean = 4.6; P = .001) and the patients were significantly older, by a mean of 4 years (67.5 vs. 71.8 years; P = .046). These results are presented in Table 3.

View this table:
  • View inline
  • View popup
  • Download powerpoint
Table 3

Comparison of the subgroups “revision surgery” and “no revision surgery.

There were no statistically significance differences in the rate or pattern of adjacent fractures when the cohort was analysed with respect to gender, number of implanted screws, broken screws, loosening of screws, cement distribution pattern and leakage, pre- and postoperative kyphosis angle, or the occurrence of adjacent fractures during follow-up. A trend was detected with respect to patient age (P = .119), T-score (P = .138) and number of fused segments (P = .199).

DISCUSSION

The augmentation of pedicle screws with cement is the gold standard for treatment of spinal pathologies requiring posterior pedicle screw instrumentation in patients with reduced bone quality. Various studies have demonstrated the advantages of cement-augmented stabilisation,4–6 which results in enhanced fixation of screws in the vertebral body. The frequency of adjacent fractures and risk factors for adjacent fracture have received little attention, despite it being self-evident that cement application to the operated vertebral body or bodies, and the fixation of 1 or more segments, may pose additional mechanical stress on adjacent vertebrae.

The aim of this study was to determine the characteristics of patients with cement-augmented pedicle screw instrumentation who developed an adjacent fracture during follow-up. Studies on this particular subject are rare and have incorporated only small patient cohorts.10–12 For this reason, we consulted previous clinical studies addressing adjacent fractures after vertebroplasty or kyphoplasty to assist us in identifying potential risk factors to investigate.

The pathogenesis of subsequent, adjacent fractures has primarily been attributed to the decreased bone density of adjacent vertebrae compared to the operated vertebrae. Phillips et al13 determined that the fusion of spinal segments in vertebroplasty and kyphoplasty surgery causes increased stress on the adjacent vertebrae. In addition, prolonged immobilisation is described as a risk factor for these fractures. There have been several studies investigating the occurrence of subsequent fractures following vertebroplasty or kyphoplasty, and rates of up to 52% are mentioned.14,15 In terms of risk factors, the application of a large volume of cement (more than 6 mL per vertebral body), intradiscal cement leakage, pronounced restoration of the vertebral body, greater age, fracture as the initial diagnosis, and reduced bone density are associated with the occurrence of adjacent fractures after vertebroplasty or kyphoplasty.16,17 In our study, we determined that clinically and radiologically apparent adjacent fractures occur following 15.1% of cement-augmented instrumentations. Several risk factors may be associated with the development of such adjacent fractures after cement-augmented instrumentation, which we now discuss.

Age

In our study, we found a slight difference in the age group (P = .119). Older patients had a higher risk of adjacent fracture. Similar results have been reported in the literature.13,14

Bone Density

Several studies have demonstrated that patients with decreased bone density have an increased risk of fracture after kyphoplasty.16,17 In our study, the T-score in the group with adjacent fractures was lower by a mean of 0.7 points compared to the group without a fracture. A trend was found (P = .137).

Patient Sex

We did not observe a sex-specific effect on the occurrence of subsequent fractures, in agreement with the preexisting literature. In a cohort of postmenopausal women, Etebar et al2 reported a high rate of adjacent segment degeneration after lumbar instrumentation without cement augmentation. Based on our retrospective data set, we were unable to determine what proportion of our cohort were postmenopausal women.

Correction of Kyphosis

In a case series examining outcomes after vertebroplasty, Rho et al16 found that a greater height restoration of the fractured vertebra is itself a risk factor for an adjacent fracture. In our study, we examined the difference between the pre- and postoperative kyphosis and compared this with the occurrence of subsequent fractures. There was no statistically significant difference in the degree of kyphosis correction between the “adjacent fracture” and “no adjacent fracture” groups.

Instrumented Level

In our study, subsequent fractures were significantly more likely to occur above the spinal fusion, equating to 85% of the fractures seen in our cohort. The findings of a cadaver study by Bastian et al,18 where the authors observed increased mobility and stress in the area above dorsal instrumentations, may provide a mechanistic basis for this finding. Increased mechanical stresses were less apparent in the level below the spondylodesis.

Cement Distribution

Hu et al19 investigated cement distribution around the screw tip after screw insertion into the vertebral body. They concluded that cement distribution (concentrated versus scattered) varies according to bone structure and density. In that study, the subgroup with scattered cement distribution had significantly higher rates of cement leakage.19 In our patient population, a scattered distribution was found in 22% of patients and we did not find a significant relationship between cement leakage and the occurrence of subsequent fracture.

Revision Spine Surgery and Long Instrumentation

We investigated whether patients undergoing revision surgery or complex, multisegment interventions were more likely to experience subsequent fracture. In our cohort, those undergoing revision surgeries did indeed experience a significantly greater number of subsequent fractures. These patients were, on average, 5 years older than those undergoing first surgery, and also had significantly more fused segments. These findings are in agreement with those of Phillips et al,13 who showed that patients with longer spinal instrumentations tended to develop subsequent fractures because of higher stress through the adjacent vertebrae.

Time of Occurrence

The vast majority of subsequent fractures, nearly 80%, were detected within the first 12 months following surgery (Figure 2), in accordance with previous literature.16 Based on this finding, it would seem sensible for patients to be monitored frequently in an outpatient setting during the first year.

Figure 2
  • Download figure
  • Open in new tab
  • Download powerpoint
Figure 2

Kaplan-Meier fracture-free probability curve for patients in whom adjacent fractures occurred.

LIMITATIONS

This was a single-center and retrospective study and therefore has inherent limitations. In addition, the mean follow-up period of 12 months is relatively short. A proportion of patients were operated on in our tertiary-level, academic center, and then returned to smaller hospitals closer to their homes, leaving them lost to intensive follow-up. Another point of criticism is that the bone density was determined retrospectively and was not determinable for every patient in our study.

CONCLUSIONS

Our findings show that cement-augmented pedicle screw instrumentations have good fixation strength in patients with reduced bone density. Patients with a very low bone density, greater age, and long instrumentation showed a trend toward a higher frequency of occurrence of adjacent fractures. Revision surgery was a risk factor for adjacent fracture and most fractures occurred above the instrumentation. Patients should be followed up regularly in the first 12 postoperative months to enable early detection of potential adjacent fractures. Clinical and biomechanical studies suggest that the occurrence of subsequent fractures may be reduced by prophylactic kyphoplasty of the upper vertebra adjacent to a multilevel lumbar fusion.20–22 In conclusion, we propose that a kyphoplasty or vertebroplasty of the upper adjacent vertebral body to an instrumentation should be discussed in patients with revision surgery to reduce the rate of a subsequent fracture.

Footnotes

  • Disclosures and COI: The authors received no funding for this study and report no conflicts of interest.

  • ©International Society for the Advancement of Spine Surgery
  • Copyright © 2018 ISASS - This manuscript is generously published free of charge by ISASS, the International Society for the Advancement of Spine Surgery

REFERENCES

  1. 1 .↵
    1. Benzel EC,
    2. Kayanja M,
    3. Fleischman A,
    4. Roy S.
    Spine biomechanics: fundamentals and future. Clin Neurosurg. 2006;53:98–105.
    OpenUrlPubMed
  2. 2 .↵
    1. Etebar S,
    2. Cahill DW.
    Risk factors for adjacent-segment failure following lumbar fixation with rigid instrumentation for degenerative instability. J Neurosurg. 1999;90(2 Suppl):163–169.
    OpenUrlPubMed
  3. 3 .↵
    1. Park P,
    2. Garton HJ,
    3. Gala VC,
    4. Hoff JT,
    5. McGillicuddy JE.
    Adjacent segment disease after lumbar or lumbosacral fusion: review of the literature. Spine. 2004;29(17):1938–1944.
    OpenUrlCrossRefPubMed
  4. 4 .↵
    1. Burval DJ,
    2. McLain RF,
    3. Milks R,
    4. Inceoglu S.
    Primary pedicle screw augmentation in osteoporotic lumbar vertebrae: biomechanical analysis of pedicle fixation strength. Spine. 2007;32(10):1077–1083.
    OpenUrlCrossRefPubMed
  5. 5 .↵
    1. Frankel BM,
    2. D'Agostino S,
    3. Wang C.
    A biomechanical cadaveric analysis of polymethylmethacrylate-augmented pedicle screw fixation. J Neurosurg Spine. 2007;7(1):47–53.
    OpenUrlCrossRefPubMed
  6. 6 .↵
    1. Sarzier JS,
    2. Evans AJ,
    3. Cahill DW.
    Increased pedicle screw pullout strength with vertebroplasty augmentation in osteoporotic spines. J Neurosurg. 2002;96(3 Suppl):309–312.
    OpenUrlPubMed
  7. 7 .↵
    1. Elder BD,
    2. Lo SF,
    3. Holmes C, et al.
    The biomechanics of pedicle screw augmentation with cement. Spine J. 2015;15(6):1432–1445
    OpenUrl
  8. 8 .↵
    1. Lattig F.
    Bone cement augmentation in the prevention of adjacent segment failure after multilevel adult deformity fusion. J Spinal Disord Tech. 2009;22(6):439–443.
    OpenUrlCrossRefPubMed
  9. 9 .↵
    1. Aydogan M,
    2. Ozturk C,
    3. Karatoprak O,
    4. Tezer M,
    5. Aksu N,
    6. Hamzaoglu A.
    The pedicle screw fixation with vertebroplasty augmentation in the surgical treatment of the severe osteoporotic spines. J Spinal Disord Tech. 2009;22(6):444–447.
    OpenUrlCrossRefPubMed
  10. 10 .↵
    1. Chang MC,
    2. Kao HC,
    3. Ying SH,
    4. Liu CL.
    Polymethylmethacrylate augmentation of cannulated pedicle screws for fixation in osteoporotic spines and comparison of its clinical results and biomechanical characteristics with the needle injection method. J Spinal Disord Tech. 2013;26(6):305–315.
    OpenUrlCrossRefPubMed
  11. 11 .
    1. Pinera AR,
    2. Duran C,
    3. Lopez B,
    4. Saez I,
    5. Correia E,
    6. Alvarez L.
    Instrumented lumbar arthrodesis in elderly patients: prospective study using cannulated cemented pedicle screw instrumentation. Eur Spine J. 2011;20(Suppl 3):408–414.
    OpenUrlPubMed
  12. 12 .↵
    1. Sawakami K,
    2. Yamazaki A,
    3. Ishikawa S,
    4. Ito T,
    5. Watanabe K,
    6. Endo N.
    Polymethylmethacrylate augmentation of pedicle screws increases the initial fixation in osteoporotic spine patients. J Spinal Disord Tech. 2012;25(2):E28–E35.
    OpenUrlCrossRefPubMed
  13. 13 .↵
    1. Phillips FM.
    Minimally invasive treatments of osteoporotic vertebral compression fractures. Spine. 2003;28(15 Suppl):S45–S53.
    OpenUrlCrossRefPubMed
  14. 14 .↵
    1. Kim MH,
    2. Lee AS,
    3. Min SH,
    4. Yoon SH.
    Risk factors of new compression fractures in adjacent vertebrae after percutaneous vertebroplasty. Asian Spine J. 2011;5(3):180–187.
    OpenUrlPubMed
  15. 15 .↵
    1. Trout AT,
    2. Kallmes DF,
    3. Kaufmann TJ.
    New fractures after vertebroplasty: adjacent fractures occur significantly sooner. AJNR. 2006;27(1):217–223.
    OpenUrlAbstract/FREE Full Text
  16. 16 .↵
    1. Rho YJ,
    2. Choe WJ,
    3. Chun YI.
    Risk factors predicting the new symptomatic vertebral compression fractures after percutaneous vertebroplasty or kyphoplasty. Eur Spine J. 2012;21(5):905–911.
    OpenUrlCrossRefPubMed
  17. 17 .↵
    1. Voormolen MH,
    2. Lohle PN,
    3. Juttmann JR,
    4. van der Graaf Y,
    5. Fransen H,
    6. Lampmann LE.
    The risk of new osteoporotic vertebral compression fractures in the year after percutaneous vertebroplasty. JVIR. 2006;17(1):71–76.
    OpenUrlCrossRefPubMed
  18. 18 .↵
    1. Bastian L,
    2. Lange U,
    3. Knop C,
    4. Tusch G,
    5. Blauth M.
    Evaluation of the mobility of adjacent segments after posterior thoracolumbar fixation: a biomechanical study. Eur Spine J. 2001;10(4):295–300.
    OpenUrlCrossRefPubMed
  19. 19 .↵
    1. Hu MH,
    2. Wu HT,
    3. Chang MC,
    4. Yu WK,
    5. Wang ST,
    6. Liu CL.
    Polymethylmethacrylate augmentation of the pedicle screw: the cement distribution in the vertebral body. Eur Spine J. 2011;20(8):1281–1288.
    OpenUrlCrossRefPubMed
  20. 20 .↵
    1. Aquarius R,
    2. Homminga J,
    3. Hosman AJ,
    4. Verdonschot N,
    5. Tanck E.
    Prophylactic vertebroplasty can decrease the fracture risk of adjacent vertebrae: an in vitro cadaveric study. Med Eng Phys. 2014;36(7):944–948.
    OpenUrl
  21. 21 .
    1. Hart RA,
    2. Prendergast MA,
    3. Roberts WG,
    4. Nesbit GM,
    5. Barnwell SL.
    Proximal junctional acute collapse cranial to multi-level lumbar fusion: a cost analysis of prophylactic vertebral augmentation. Spine J. 2008;8(6):875–881.
    OpenUrlCrossRefPubMed
  22. 22 .↵
    1. Kayanja MM,
    2. Schlenk R,
    3. Togawa D,
    4. Ferrara L,
    5. Lieberman I.
    The biomechanics of 1, 2, and 3 levels of vertebral augmentation with polymethylmethacrylate in multilevel spinal segments. Spine. 2006;31(7):769–774.
    OpenUrlPubMed
PreviousNext
Back to top

In this issue

International Journal of Spine Surgery
Vol. 12, Issue 5
1 Oct 2018
  • Table of Contents
  • Index by author

Print
Download PDF
Article Alerts
Sign In to Email Alerts with your Email Address
Email Article

Thank you for your interest in spreading the word on International Journal of Spine Surgery.

NOTE: We only request your email address so that the person you are recommending the page to knows that you wanted them to see it, and that it is not junk mail. We do not capture any email address.

Enter multiple addresses on separate lines or separate them with commas.
Risk Factors for Adjacent Fractures After Cement-Augmented Thoracolumbar Pedicle Screw Instrumentation
(Your Name) has sent you a message from International Journal of Spine Surgery
(Your Name) thought you would like to see the International Journal of Spine Surgery web site.
CAPTCHA
This question is for testing whether or not you are a human visitor and to prevent automated spam submissions.
Citation Tools
Risk Factors for Adjacent Fractures After Cement-Augmented Thoracolumbar Pedicle Screw Instrumentation
FALKO SCHWARZ, MICHAELA BURCKHART, AARON LAWSON MCLEAN, ROLF KALFF, ALBRECHT WASCHKE
International Journal of Spine Surgery Oct 2018, 12 (5) 565-570; DOI: 10.14444/5069

Citation Manager Formats

  • BibTeX
  • Bookends
  • EasyBib
  • EndNote (tagged)
  • EndNote 8 (xml)
  • Medlars
  • Mendeley
  • Papers
  • RefWorks Tagged
  • Ref Manager
  • RIS
  • Zotero
Share
Risk Factors for Adjacent Fractures After Cement-Augmented Thoracolumbar Pedicle Screw Instrumentation
FALKO SCHWARZ, MICHAELA BURCKHART, AARON LAWSON MCLEAN, ROLF KALFF, ALBRECHT WASCHKE
International Journal of Spine Surgery Oct 2018, 12 (5) 565-570; DOI: 10.14444/5069
Twitter logo Facebook logo Mendeley logo
  • Tweet Widget
  • Facebook Like
  • Google Plus One

Jump to section

  • Article
    • ABSTRACT
    • INTRODUCTION
    • MATERIALS AND METHODS
    • RESULTS
    • DISCUSSION
    • LIMITATIONS
    • CONCLUSIONS
    • Footnotes
    • REFERENCES
  • Figures & Data
  • Info & Metrics
  • PDF

Related Articles

  • No related articles found.
  • PubMed
  • Google Scholar

Cited By...

  • No citing articles found.
  • Google Scholar

More in this TOC Section

  • Recovery Trajectories After Lumbar Fusion Stratified by Baseline Patient-Reported Outcomes Measurement Information System Physical Function Disability Levels
  • Safety and Viability of Anterior Lumbar Interbody Fusion in Complex Revision Lumbar Spine Surgeries: Insights From a Case Series of 135 Patients on Transforaminal Lumbar Interbody Fusion/Posterior Lumbar Interbody Fusion Cage Removal
  • Effects of Body Mass Index on Spondylolisthesis Surgery and Associated Patient-Reported Outcomes: A Retrospective Review
Show more Lumbar Spine

Similar Articles

Keywords

  • adjacent fracture
  • spine surgery
  • osteoporosis
  • cement-augmented
  • pedicle screw instrumentation

Content

  • Current Issue
  • Latest Content
  • Archive

More Information

  • About IJSS
  • About ISASS
  • Privacy Policy

More

  • Subscribe
  • Alerts
  • Feedback

Other Services

  • Author Instructions
  • Join ISASS
  • Reprints & Permissions

© 2025 International Journal of Spine Surgery

International Journal of Spine Surgery Online ISSN: 2211-4599

Powered by HighWire